Comparison
SAFL Baffle vs Hydro Dynamic Separators
Attribute |
SAFL Baffle |
Hydro Dynamic |
Flow Performance (CFS): | 80 Cubic Feet per Second | 8 Cubic Feet per Second |
TSS Removal Efficiency: | 84% | 85% |
Maintenance: | No Maintenance | Requires Routine Maintenance |
Longevity: | Guaranteed 20 Years | No Guarantee |
Materials: | All Stainless Steel (No Plastic) | Plastic |
Ease of Cleanout: | Easy | Complicated |
By-Pass Required? | NO | YES |
Cost: | $5,000 | $24,000 |
The Minnesota DOT switched from Hydro-Dynamic Separators to the SAFL Baffle and in 3 Years, saved the taxpayers over $8 Million Dollars!
The SAFL Baffle:
- Provides lowest cost per pound sediment removal
- High Performance: 80 CFS
- Long Life - Guaranteed 20 years
Typical comparison found on over 1000 projects |
SAFL Baffle | Hydro Dynamic Separators |
Cost: | $5,200 |
TSS Removal Efficiency: | 84% |
By-Pass Flow Rate: | 80 CFS |
|
Cost: | $24,00 |
TSS Removal Efficiency: | 85% |
By-Pass Flow Rate: | 8 CFS |
|
Operates by stopping the vortex
The SAFL Baffle stops the natural vortex that is created in standard sump structures,
dissipating hydro energy and causing sediment to drop to the bottom of the sump.
As sediment collects in the bottom, the SAFL Baffle's design prevents vortex scouring
and resuspension, retaining all previously captured sediment, even during
high-flow storm events up to 80 cubic feet per second.
| Operates by creating a vortex
Hydro Dynamic Separators operate with average flows of 8 cubic feet per second.
At greater flows, stormwater bypasses the device and does not capture any sediment.
Internal plastic parts are prone to vibrate and break.
SAFL Baffles can, and have been, retrofitted in existing hydrodynamic structure for a cost-effective replacement.
|
|
Baffle Home
SAFL Baffle is Patented
CERTIFICATIONS
NJCAT Verified NJDEP Certified
Download the NJCAT PDF
Indianapolis Certification
20 Year Guarantee (PDF)
100% Steel Construction (PDF)
SAFL Baffle Brochure (PDF)
Made in the USA (PDF)
Build America Buy America Certificate(PDF)
Baffle Sizes
Compare Hydrodynamic
Installation Map
Typical Detail
Design Guides
Sediment, Trash & Oil Tips:
Over 80% TSS Removal
Baffle Installation
Rigorous Testing
- Trash & Anti-Clogging
- Multiple Inlet Pipes
- Angled Pipes
SAFL Baffle Research & Testing Documents
MnDOT Reports the SAFL Baffle has saved Minnesota Tax Payers more than $8 million dollars in the last 3 years and
expects to save another $26 million over the next 10 years.
(See:
MnDOT Report Pages 41-43) (Full Document here)
|